Solutions > Manage application monitor templates and component monitors

Manage application monitor templates and component monitors

SAM includes a number of out-of-the-box templates to assign to nodes as needed. Templates include component monitors for specific applications or for scripts, grouped by application categories. SolarWinds recommends creating a copy of these templates to customize, remove, or add component monitors.

You can also create, modify, and configure Application Monitor templates for customized monitoring. To create templates:

  • Create new templates using copies of OOTB templates
  • Create a template from scratch
  • Import and customize templates from THWACK

To work with templates and monitors, see the following:

For details on application templates and monitors, see SAM Component Monitor Types and SAM Template Reference.

Component Monitors

Component monitors are the building blocks of SolarWinds SAM. Each monitors the status and performance of a different aspect of an application. There are several different types of component monitors, each containing settings that define what is monitored and how to monitor it.

Some types of component monitors allow you to set threshold conditions on the monitored parameters. You can set separate thresholds to indicate warning and critical conditions. For example, if you are monitoring the percentage of free space remaining on a volume, you can set a warning threshold at 15%, and a critical condition at 5%.

As an analogy, pretend SolarWinds SAM is monitoring a car. You would have component monitors to check tire pressure, engine RPM, water temperature, battery voltage, and other important subsystems of that vehicle. You can set alerts to give notification if the water gets too hot, or if the battery voltage drops too low.

Application Monitor Templates

A template is a group of component monitors modeling the total availability and performance level of an application. A complicated application such as Windows Server may require dozens of component monitors to accurately assess its current status and performance.

Instead of creating component monitors one-by-one for every application server, you can assign a pre-made template. The template can either be one included with SolarWinds SAM, or a custom template you make yourself. For example, you can assign the included Microsoft Windows Server 2003-2008 template to your Windows 2003 and Windows 2008 computers and obtain vital statistics on all of them.

A template is only a blueprint and does not perform any monitoring on its own. Only after assigning the template to a server node are active assigned component monitors created.

To continue the car analogy, pretend you want to monitor a fleet of 50, 2010, blue Dodge Charger automobiles. Instead of defining the component monitors for 50 cars, you can define all the component monitors in a Dodge Charger template.

Assigned Component Monitors

Assigned component monitors are created by assigning Application Monitor templates to server nodes. Each actively monitors its assigned node according to its settings. Component monitors inherit these initial settings from the template. If you make a change to a template, that same change is rolled out to all assigned Application Monitors based on the template.

You can override the template settings at any time, breaking the inheritance relationship between the component monitor and its template. For example, the user name and password usually differ for each node, and you would select a different credential for each assigned Application Monitor, thus overriding the template setting for the Credentials field.

To restore the inheritance relationship between a component monitor and its template, click Inherit From Template next to the setting.

Continuing the car analogy, when you assign the Dodge Charger template to a Dodge Charger vehicle, you now have a set of assigned component monitors for monitoring the vehicle’s tire pressures, engine RPM, and so forth.

Assigned Application Monitors

An assigned Application Monitor runs its assigned component monitors at regular intervals, and then uses the status results from the component monitors to determine an overall status for the application.

If some of the component monitors are up and others are down, the Application Monitor follows the Status Rollup Mode setting in the SolarWinds Web Console Settings to show either the worst status of the group or a warning status.

The difference between an assigned Application Monitor and a template is that the template is only a blueprint and does not perform any monitoring on its own. Only after assigning the template to a server node does SolarWinds SAM conduct any actual monitoring on the node.

To complete the car example, you assign the Dodge Charger template to all the Dodge Charger vehicles to create the assigned Application Monitor for determining the overall status for your Dodge Charger fleet. For example, the fleet may be 95% available at a given time due to warnings for some of the cars.

The following diagram illustrates the work flow involved in creating an application to be monitored by SAM.